~bzr-pqm/bzr/bzr.dev

« back to all changes in this revision

Viewing changes to bzrlib/smart/signals.py

  • Committer: Canonical.com Patch Queue Manager
  • Date: 2010-08-24 23:20:14 UTC
  • mfrom: (5365.5.29 2.3-btree-chk-leaf)
  • Revision ID: pqm@pqm.ubuntu.com-20100824232014-nu9owzel2zym2jk2
(jam) Use a custom C type for CHK index entries, saves memory

Show diffs side-by-side

added added

removed removed

Lines of Context:
1
 
# Copyright (C) 2011 Canonical Ltd
2
 
#
3
 
# This program is free software; you can redistribute it and/or modify
4
 
# it under the terms of the GNU General Public License as published by
5
 
# the Free Software Foundation; either version 2 of the License, or
6
 
# (at your option) any later version.
7
 
#
8
 
# This program is distributed in the hope that it will be useful,
9
 
# but WITHOUT ANY WARRANTY; without even the implied warranty of
10
 
# MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE.  See the
11
 
# GNU General Public License for more details.
12
 
#
13
 
# You should have received a copy of the GNU General Public License
14
 
# along with this program; if not, write to the Free Software
15
 
# Foundation, Inc., 51 Franklin Street, Fifth Floor, Boston, MA 02110-1301 USA
16
 
 
17
 
"""Signal handling for the smart server code."""
18
 
 
19
 
from __future__ import absolute_import
20
 
 
21
 
import signal
22
 
import weakref
23
 
 
24
 
from bzrlib import trace
25
 
 
26
 
 
27
 
# I'm pretty sure this has to be global, since signal handling is per-process.
28
 
_on_sighup = None
29
 
# TODO: Using a dict means that the order of calls is unordered. We could use a
30
 
#       list and then do something like LIFO ordering. A dict was chosen so
31
 
#       that you could have a key to easily remove your entry. However, you
32
 
#       could just use the callable itself as the indexed part, and even in
33
 
#       large cases, we shouldn't have more than 100 or so callbacks
34
 
#       registered.
35
 
def _sighup_handler(signal_number, interrupted_frame):
36
 
    """This is the actual function that is registered for handling SIGHUP.
37
 
 
38
 
    It will call out to all the registered functions, letting them know that a
39
 
    graceful termination has been requested.
40
 
    """
41
 
    if _on_sighup is None:
42
 
        return
43
 
    trace.mutter('Caught SIGHUP, sending graceful shutdown requests.')
44
 
    for ref in _on_sighup.valuerefs():
45
 
        try:
46
 
            cb = ref()
47
 
            if cb is not None:
48
 
                cb()
49
 
        except KeyboardInterrupt:
50
 
            raise
51
 
        except Exception:
52
 
            trace.mutter('Error occurred while running SIGHUP handlers:')
53
 
            trace.log_exception_quietly()
54
 
 
55
 
 
56
 
def install_sighup_handler():
57
 
    """Setup a handler for the SIGHUP signal."""
58
 
    if getattr(signal, "SIGHUP", None) is None:
59
 
        # If we can't install SIGHUP, there is no reason (yet) to do graceful
60
 
        # shutdown.
61
 
        old_signal = None
62
 
    else:
63
 
        old_signal = signal.signal(signal.SIGHUP, _sighup_handler)
64
 
    old_dict = _setup_on_hangup_dict()
65
 
    return old_signal, old_dict
66
 
 
67
 
 
68
 
def _setup_on_hangup_dict():
69
 
    """Create something for _on_sighup.
70
 
 
71
 
    This is done when we install the sighup handler, and for tests that want to
72
 
    test the functionality. If this hasn'nt been called, then
73
 
    register_on_hangup is a no-op. As is unregister_on_hangup.
74
 
    """
75
 
    global _on_sighup
76
 
    old = _on_sighup
77
 
    _on_sighup = weakref.WeakValueDictionary()
78
 
    return old
79
 
 
80
 
 
81
 
def restore_sighup_handler(orig):
82
 
    """Pass in the returned value from install_sighup_handler to reset."""
83
 
    global _on_sighup
84
 
    old_signal, old_dict = orig
85
 
    if old_signal is not None:
86
 
        signal.signal(signal.SIGHUP, old_signal)
87
 
    _on_sighup = old_dict
88
 
 
89
 
 
90
 
# TODO: Should these be single-use callables? Meaning that once we've triggered
91
 
#       SIGHUP and called them, they should auto-remove themselves? I don't
92
 
#       think so. Callers need to clean up during shutdown anyway, so that we
93
 
#       don't end up with lots of garbage in the _on_sighup dict. On the other
94
 
#       hand, we made _on_sighup a WeakValueDictionary in case cleanups didn't
95
 
#       get fired properly. Maybe we just assume we don't have to do it?
96
 
def register_on_hangup(identifier, a_callable):
97
 
    """Register for us to call a_callable as part of a graceful shutdown."""
98
 
    if _on_sighup is None:
99
 
        return
100
 
    _on_sighup[identifier] = a_callable
101
 
 
102
 
 
103
 
def unregister_on_hangup(identifier):
104
 
    """Remove a callback from being called during sighup."""
105
 
    if _on_sighup is None:
106
 
        return
107
 
    try:
108
 
        del _on_sighup[identifier]
109
 
    except KeyboardInterrupt:
110
 
        raise
111
 
    except Exception:
112
 
        # This usually runs as a tear-down step. So we don't want to propagate
113
 
        # most exceptions.
114
 
        trace.mutter('Error occurred during unregister_on_hangup:')
115
 
        trace.log_exception_quietly()
116